Direct USB
Connection. (Max 5 M Cable)
Works with USB voltage 5Volt 185ma (do
not need an external voltage )
65db Arc voltage filter, For cur
voltage input
CNC program controlled on/off M3/M5 & THC On/off
Auto Antidive protection & Antidive Speed
calibration DRO (Set File)
Cur voltage sens Low voltage input 0to10volt or
50 to340v standart Cur voltage
The system will respond to arc voltage changes of less
than 340/5 volt.
Regular speed of retract exceeds 200 ipm (5.0 m/norm)Over-voltage
protection automatically eliminates "torch diving"
during large, out-of-limits
Arc voltage fluctuations; such as kerf crossings or
cutting off the edge of a plate
(G28.1) For mach3 plasa Built-in probe touch-retract
initial height sensing (IHS) (Set File)
Feature ensure saccurate, repeatable initial piercing
height settings...
Plasma system interface module (Set. File For Mach3
Plasma program)
|
(Torch Height Control) yada AHTC (Automatic
THC) adı verilen bir sistemle kesme süresince Yükseklik
istenilen seviyede ayarlanabilmektedir.Ark gerilimi geri
beslemesi saniyede 200 keze varan oranlara
erişebilmektedir. THC160V2 ve THC 160V3
Mach3 CNC Plazma Programına
entegre Olarak Çalışmaktadır LPT1 ve usb2 ile bağlantı
yapmaktadır. 0-340v 0-10v converter ile Direk cur
voltajını okuyabilmektedir
|